HetBased
SCPI Commands :
INITiate:WLAN:SIGNaling<instance>:HETBased
STOP:WLAN:SIGNaling<instance>:HETBased
ABORt:WLAN:SIGNaling<instance>:HETBased
- class HetBasedCls[source]
HetBased commands group definition. 5 total commands, 2 Subgroups, 3 group commands
- abort() None [source]
# SCPI: ABORt:WLAN:SIGNaling<instance>:HETBased driver.hetBased.abort() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
- abort_with_opc(opc_timeout_ms: int = -1) None [source]
# SCPI: ABORt:WLAN:SIGNaling<instance>:HETBased driver.hetBased.abort_with_opc() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
Same as abort, but waits for the operation to complete before continuing further. Use the RsCmwWlanSig.utilities.opc_timeout_set() to set the timeout value.
- param opc_timeout_ms:
Maximum time to wait in milliseconds, valid only for this call.
- initiate() None [source]
# SCPI: INITiate:WLAN:SIGNaling<instance>:HETBased driver.hetBased.initiate() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
- initiate_with_opc(opc_timeout_ms: int = -1) None [source]
# SCPI: INITiate:WLAN:SIGNaling<instance>:HETBased driver.hetBased.initiate_with_opc() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
Same as initiate, but waits for the operation to complete before continuing further. Use the RsCmwWlanSig.utilities.opc_timeout_set() to set the timeout value.
- param opc_timeout_ms:
Maximum time to wait in milliseconds, valid only for this call.
- stop() None [source]
# SCPI: STOP:WLAN:SIGNaling<instance>:HETBased driver.hetBased.stop() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
- stop_with_opc(opc_timeout_ms: int = -1) None [source]
# SCPI: STOP:WLAN:SIGNaling<instance>:HETBased driver.hetBased.stop_with_opc() INTRO_CMD_HELP: Starts, stops, or aborts the measurement: - INITiate... starts or restarts the measurement. The measurement enters the 'RUN' state. - STOP... halts the measurement immediately. The measurement enters the 'RDY' state. Measurement results are kept. The resources remain allocated to the measurement. - ABORt... halts the measurement immediately. The measurement enters the 'OFF' state. All measurement values are set to NAV. Allocated resources are released.
Use FETCh…STATe? to query the current measurement state.
Same as stop, but waits for the operation to complete before continuing further. Use the RsCmwWlanSig.utilities.opc_timeout_set() to set the timeout value.
- param opc_timeout_ms:
Maximum time to wait in milliseconds, valid only for this call.
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.hetBased.clone()
Subgroups